Otowave Tymp 102
Tympanometry Measurements:
Probe Tone Levels: 226 Hz ± 2%, 85 dBSPL ± 2 dB, over range 0.2 ml to 5 ml
Pressure Range:
+200 daPa to -400 daPa ± 10 daPa
Ear Volume Measurement:
Range 0.2 ml to 5 ml ± 0.01 ml or 10 % (whichever is larger) over entire range
Reflex Measurement Range Reflex DB Range:
500 Hz, 1 kHz, 2 kHz, 4 kHz Frequency ± 0.1 %
85 to 100 dbHL (programmable in 5 or 10 dB steps)
Reflex Measurement Range:
0.01 ml to 0.5 ml ± 0.01 ml configurable in 0.01 ml steps
Standards:
Safety IEC 60601-1; EMC IEC 60601-1-2
Impedance IEC 60645-5 Type 2 Tympanometer ANSI 3.39
CE Mark Complies to EU Medical Device Directive
Power:
Battery 4 x Alkaline AA cells or 4 x NiMH (<=2.3Ah) rechargeable
Dimensions:
Approx. 21 x 8 x 4 cm
Weight:
380 Gram
Standard Accessories 102:
Rugged Transportable Carrying Case, Test Cavities, Set of Disposable Eartips,4 x 1.5V Rechargeable NIMH Batteries, Battery Charging System, Operator’s Manual. Optional Accessories: Wireless IR Printer, Infra-red USB Adapter


Otowave Tymp 202-201H
Tympanometry Measurements:
Probe Tone Levels: 226 Hz ± 2%, 85 dB SPL ± 2 dB 1000 Hz ± 2%; 79 dB SPL ± 2 dB (202-H only) over ear canal volume range
Pressure Range:
+200 daPa to -400 daPa ± 10 daPa or ± 10% (whichever is larger) over range 0.1ml to 5ml
Ear Volume Measurement Range:
226 Hz: 0.2 ml to 5 ml ; 1000 Hz: 0.1 ml to 5ml ± 0.1ml or ± 5% (whichever is larger)
Reflex Measurement Range Reflex DB Range:
5Ipsilateral and contralateral or both User-selectabele from: 500 Hz, 1 kHz, 2 kHz and 4 kHz (±2 %) Reflex levels: Ipsilateral: 70 dBHL to 110 dBHL (±3dB) Contralateral: 70 dBHL to 110 dBHL (±3dB)
Reflex Measurement Range:
0.01 ml to 0.5 ml ± 0.01ml configurable in 0.01ml steps
Standards:
Safety IEC 60601-1; EMC IEC 60601-1-2
Impedance IEC 60645-5 Type 2 Tympanometer ANSI S3.39
CE Mark Complies to EU Medical Device Directive
Power:
Mains: 100-240 VAC; 50/60 Hz via mains adapter (approved in medical safety standards); Batteries: 4 x AA (either Alkaline or NiMH, the latter recharged external to the instrument )
Dimensions:
Base unit: 19 x 8.5 x 4 cm (excluding connections)
Probe: 13 x 2.5 cm (max.) diameter
Weight:
Base unit: 330 g (without batteries, using mains power), 430 g (with batteries), Probe: 110 g (incl. connecting cable)
Standard Accessories 202-202H:
Test cavities, 4 x 1.5 V Alkaline AA batteries, Contralateral transducer, Set of disposable ear tips, Carrying Case, MedRx NOAH impedance module, USB cable, Mains adapter, Operating Manual

 

 

 

 


MedRx Otowave Tymp

Otowave Tymps

The MedRx Otowave 102 and 202 form a comprehensive range of screening and diagnostic Tympanometers


Tympanometer Screen ShotOtowave 102
Hand-Held Screening Tympanometry This wireless hand-held Tympanometer with large screen provides 226 Hz probe tone impedance measurement including 4 acoustic reflex frequencies. Results are stored internally (up to 30 records). All data can be transfered to a PC via the MedRx software module and IR dongle. The software is NOAH™ compatible.

Otowave 202 / 202-H
Functionality There are two versions of the Otowave 202 available: The standard Otowave 202 provides 226 Hz probe tone impedance measurements together with a user programmable range of both ipsi and contra lateral reflex test measurements at 500 Hz, 1 kHz, 2 kHz and 4 kHz.

The Otowave 202-H option features a comprehensive range of test functions including user defined 226 Hz and 1 kHz probe tone impedance measurements and a user programmable range of both ipsi and contra lateral reflex test measurements at 500 Hz, 1 kHz, 2 kHz and 4 kHz.

Advanced Tympanometry The Otowave 202 provides fast, objective middle ear measurements to assist with the identification of middle ear disorders in neonates, children and adults. When using the Otowave 202 in 226 Hz probe tone mode, the compliance peak, compliance peak pressure, gradient and ear canal volume can be measured within seconds.

When using the Otowave 202-H option in 1 kHz probe tone mode, users can easily select a preferred display by simply pressing the probe function key to switch between:
• Scalar mode: a traditional admittance tympanogram (Y only compensation)
• Vector mode: a tympanogram displaying B-G compensation
• Component mode: the separate admittance (Y), susceptance (B) and conductance (G) measurements are displayed for clinical review. The ear canal volume is displayed whenever 1 kHz mode is selected.

Otowave Tymp Product Flyer
Hearing Healthcare Catalog


 Training Manuals: Otowave 102 Rev 14 | Otowave 202 & 202H Rev 3